Digital input/output and analog input connections

The IX40 has an input/output connector with four digital input/output connections, and four analog input connections.

I/O connector pin assignments

The figure and table show the I/O connector, pin assignments, and the signals for each pin.

Symbol Description
AIN1

Analog Input 1

AGND

Analog Return

AIN2

Analog Input 2

GND

Analog Return

DIO1

Analog Input 3

DIO2

Analog Return

 

IX40 digital input/output: representative circuit

IX40 analog input: representative circuit

Example digital and analog I/O wiring

Digital input with pullup

Digital input without pullup

Note that input is HIGH when the contact is CLOSED.

Digital output

The wiring diagram assumes a current-limiting resistor provided by installation or connected device is in use.

Analog input, 4-20mA input mode

Analog input, 0-10V input mode

Digital and analog I/O specifications

Digital I/O specifications

Specification

Min

Nom

Max

Units

Rated Input Voltage

-1.5

 

18.5

V

Rated Input Current

-1.0

 

1001

mA

Pull-Up Resistance

 

10 k

 

Ohms

1 The current limiter is limiting over 30mA.

Digital input specifications

Specification

Min

Nom

Max

Units

+ Threshold

..

2

..

V

- Threshold

..

1.1

..

V

Input impedance

..

4.7M

..

Ohms

Digital output

Specification

Min

Nom

Max

Units

Sink Current

..

..

200

mA

Pull-up Voltage

 

3.3

 

V

Analog input specifications

Specification

Min

Nom

Max

Units

Resolution

..

..

12

BITS

Accuracy

..

..

0.2

%

Rated Input Voltage

-0.2

 

30

V

Rated Input Current

0

 

40

mA

Voltage input mode (default)

Specification

Min

Nom

Max

Units

Input Voltage

-0.2

..

10.5

V

Input Impedance

..

253K

..

Ohms

Current loop mode

Specification

Min

Nom

Max

Units

Minimum Input Voltage

..

2

..

V

Load Resistance

..

200

..

Ohms